precision wedge mounts free-standing (FS) - assembly instruction
We kindly ask to read the below carefully prior to assembly / installation of the precision wedge mounts.
The load data given in the precision wedge mount catalogue are valid for static load.
Height adjustment under load can be facilitated with highly reduced torque by adjusting from the top-most levelling height of the wedge mount downwards and thus making use of gravity.
Prior to assembly / installation, we recommend to adjust the wedge mount to the top-most levelling height. In operation, the ideal levelling height to be achieved is the middle levelling height.
All parts have to be aligned interlockingly with their respective guide keys and grooved keyways.
The precision wedge mounts free-standing (FS) are designed for simple slide-underneath installation, consisting of 3 losely stacked wedge parts. Depending on the application, top and bottom are equipped with dampening and non-slip protection boards of various shorehardnesses and optional surface structure. In operation, the thinner elastomer board faces up towards the machine frame.
As described above, height adjustment is facilitated starting from the top-most levelling height, proceeding downwards.