description | article number | A(mm) | b(mm) | d(mm) | D(mm) | D1(mm) | H0(mm) | Ni(mm) | G | T(mm) | operation pressure(bar) | load(daN) |
---|
FLN 65/FS | 7001 0009 | 75 | 60 | 7 | 73 | 28 | 65 | ± 5 | M 10 | 3 | 1,5 - 5 | 15 - 65 |
FLN 180/FS | 7001 0010 | 105 | 89 | 7 | 105 | 52 | 65 | ± 5 | M 12 | 3 | 1,5 - 5 | 50 - 180 |
FLN 280/FS | 7001 0011 | 130 | 108 | 7 | 127 | 60 | 90 | ± 6 | M 12 | 3 | 1,5 - 6 | 70 - 280 |
FLN 600/FS | 7001 0012 | 175 | 153 | 7 | 172 | 96 | 90 | ± 6 | M 12 | 3 | 1,5 - 6 | 150 - 600 |
FLN 1300/FS | 7001 0013 | 255 | 215 | 14 | 245 | 138 | 90 | ± 6 | M 16 | 5 | 1,5 - 6 | 300 - 1300 |
FLN 2600/FS | 7001 0014 | 343 | 305 | 14 | 338 | 205 | 90 | ± 6 | M 16 | 5 | 1,5 - 6 | 600 - 2600 |
FLN 5500/FS | 7001 0015 | 470 | 406 | 20 | 468 | 300 | 90 | ± 6 | M 24 | 6 | 1,5 - 6 | 1200 - 5500 |
FLN 10000/FS | 7001 0016 | 610 | 508 | 20 | 610 | 430 | 90 | ± 6 | M 24 | 6 | 1,5 - 6 | 2500 - 10000 |
The element size should be chosen in such fashion, that under the given load, the maximum allowed operational pressure of 5 to 6 bar is not exceeded. The overlaying maximum dynamic load should also not transgress the maximum allowed operational load. Best isolation grades are achieved, if over-dimensioning is avoided.
Including screw DIN 933/ISO 4017, large nut DIN 934 and small washer DIN 125/ISO 7089 for fastening the air-cushion vibration damper to the machine.
By default, the air-cushion vibration dampers FLN are supplied in a pressure-less state. After mounting, height H is adjusted by administering compressed air, with a maximum of 5 bar respectively 6 bar, in a range of +/- 5 mm respectively +/- 6 mm.
Prior to de-loading, the element must be completey de-ventilated.
To be noted: for the air-cushion dampers of the series FLN, it is compulsory to fasten them to the to-be-isolated machine via the included mounting screw DIN 933 ( refer to assembly instruction ).
In addition, we would like to recommend the general application of the optional mounting plates, for a full-faced covering of the air-cushion dampers. This facilitates protection against sinking-in, should a loss of pressur occur.